We would like to introduce you a special limited edition of ten DC/DS-24 transmitters, which was created for the 75th anniversary of the end of World War II. Unfortunately, the release of this series last year was significantly affected by a global pandemic, which also affected our plans. The limited edition is intended for end customers, collectors and fans of JETI and is created in the spirit of flying legends of World War II. Each transmitter has original design, which was artistically painted directly on the transmitter (Airbrush).
You can find more information and photos on our Facebook profile JETI Model.

1. REX Assist v1.19 (03/2021)
Airplane pitch with Assist enabled is no longer affected by acceleration (Horizon mode).
2. MVario2 FAI F5J v2.05 (03/2021)
Supports new sensor revision.

-Time interval of the RX alarm was modified to 2s.
-Extension the compatibility for Futaba R7008SB (S.BUS)
The update can be done by the Jeti Studio.
MUI30 EX
Weight [g] | 10 |
Dimensions [mm] | 20 x 16,5 x 5 |
Operational temperature [°C] | -10 ... 85 |
Supply Voltage [V] | 5 ... 8,4 |
Average Current [mA] | 24 |
Range of measured voltage [V] | 0 ... 60 |
Range of measured current [A] | 0 ... 30 |
Accuracy of voltage measurement [%] | 0,1 |
Accuracy of current measurement [%] | 1 |
Files for download
Update - Sensors
Manuals - MUI EX
For communication purposes the Duplex system takes advantage of the 2,4 GHz band which, besides sending remote control data to the model, also receives data from the model back to the transmitter. During a flight, obtained telemetric data are transmitted in real time and the actual values of the measured data can be displayed on the JETIBOX LCD. Telemetric MUI sensors execute voltage and current measurements in your model and transmit these informations with the aid of the DUPLEX system (receivers and transmitter modules). Thanks to exact current measurements these sensors make it possible to trace the spent capacity of the measured battery. The MUI unit is recording the spent current flow time and its average as well as maximum value. Furthermore it offers exact voltage measurements and recordings of voltage minimum and maximum values.
The task of parameter adjustment and measured data setup is performed by the well known talent – the JETIBOX terminal.
MUI sensors allow setting of acoustical signals in order to announce violation of set parameters. Such alarms may be set for measuremets of maximum current and minimum voltage as well as for a maximum of consumed battery capacity. The sound signal is generated by a siren integrated in the transmitter module. For better differentiation the particular alarms are distinguished by Morse alphabetic letters. The acoustical alarm generation in case of parameter violation is working even if the JETIBOX is not connected. With the JETIBOX in place, the LCD display shows which parameter has been violated. In case of violation of several parameters the alerts alter consecutively as well as the indications on the LCD display.